How to Repair a Plaster and Lath Wall With Drywall (Phoenix Homeowner Guide)
Replace a failing section of an old plaster and lath wall with drywall: test for lead and asbestos, cut back to sound plaster, shim to match, fasten to code and blend the seams.
By Gabriel · Licensed Phoenix, Arizona General Contractor ROC 367058 (R-62) · 2026-11-24

Plaster walls are hard and quiet, but after decades the plaster can lose its grip on the wood lath behind it. You see long cracks, bulges that move when you push them, and pieces that fall off and show the lath strips underneath, like the wall in the photo above. Some older Phoenix homes, especially in the historic neighborhoods near downtown, still have plaster walls, and many homes people buy and remodel were built before drywall was common.
When a section is too far gone to re-attach, the usual fix is to cut the bad plaster back to sound material and fill the opening with drywall built out to the same thickness, so the new board sits flush with the old wall. Below is the order I follow. Each step says why it matters and which code section it comes from. For a small hole in a drywall wall, see my guide on how to patch a hole in drywall; for the finishing work, see how to tape and mud drywall joints. If you would rather have it done, see my drywall hole and crack repair service. This guide is for plaster on wood lath; plaster applied directly to brick, block or adobe is a different repair.
Tools and parts
- Lead test kit (EPA-recognized) and a lab test or inspector for possible asbestos
- Plastic sheeting, painter's tape, drop cloths and a HEPA shop vacuum
- Fitted respirator (N95 or better), safety glasses, gloves and hearing protection
- Non-contact voltage tester and a stud finder
- Oscillating multitool with a carbide or diamond plaster blade, utility knife and a 4 ft straightedge
- Hammer, flat pry bar, cat's paw or nail puller, and a stiff brush
- Drywall in thicknesses that stack up to the old wall (1/4, 3/8 and 1/2 in. are common) or furring strips and shims
- Type W drywall screws long enough for at least 5/8 in. of wood penetration through the build-up
- Drill/driver with a drywall screw setter
- Box extenders or extension rings for any electrical box in the wall
- Plaster washers or plaster screws for loose plaster next to the opening
- Setting-type joint compound, paper or mesh tape, ready-mix compound and a primer for the skim coat
- 6, 10 and 12 in. taping knives, a mud pan and sanding sponges
Step-by-step
Test for lead and asbestos before you break any plaster
If the house was built before 1978, test the paint on the wall with an EPA-recognized lead test kit, or have it tested. If the walls or ceiling were patched or textured before the late 1970s, have a sample of the patching material and texture tested by a qualified lab before you cut, sand or scrape. Keep the test results.
Why: Breaking and sanding plaster turns paint and old compound into fine dust. Federal rules require contractors working for pay in pre-1978 homes to use lead-safe practices on anything larger than about 6 square feet of painted surface in a room, which tells you how seriously lead dust is taken. The CPSC banned patching compounds with added asbestos in 1977-1978, so older patch and joint compound can still contain it. You cannot tell by looking; only a test can.
Code: EPA RRP Rule, 40 CFR Part 745 Subpart E (pre-1978 homes; 6 sq ft interior minor-repair limit) · CPSC 16 CFR 1304.4 (asbestos patching compounds banned 1978)
Decide what you are fixing: re-attach, patch or replace the section
Push on the plaster around the damage. Cracked but solid plaster can be re-attached with plaster washers or screws and skim-coated. A doorknob hole or a small break can be patched. When the plaster moves, sounds hollow over a large area, or has fallen off and exposes the lath, replace that section with drywall. Mark the outline of the sound plaster with a pencil and a straightedge so you know how big the opening will be.
Why: Phoenix does not require a building permit for minor repair of non-structural parts such as patching walls or ceilings, or for finish work like painting. Re-attaching and patching keep you in that category. If the job grows into removing whole walls, moving framing or opening the wall for new wiring or plumbing, it is no longer a minor patch, so check with the city before you start.
Code: Phoenix PBCC Admin. 105.2, Building item 18 (minor repair, patching walls or ceilings) · Phoenix PBCC Admin. 105.2, Building item 7 (painting and similar finish work)

Shut off the power and find the wires and pipes behind the lath
Turn off the breakers for the receptacles, switches and lights on that wall and on the other side of it, and confirm with a non-contact tester. Look at where the boxes, light fixtures and plumbing fixtures are and assume wires and pipes run between them. Cut the plaster shallow at first and look into the opening before you go deeper. Old cloth-covered or knob-and-tube wiring is a sign to stop and call an electrician.
Why: In old houses the wiring often runs right behind the lath, closer to the surface than modern code allows. Today the code wants a cable running along a stud kept at least 1-1/4 inches back from the face where nails and screws go, or covered with a steel plate, and holes in studs bored at least 1-1/4 inches from the edge. Old work often does not meet that, so a saw blade or a screw can hit it.
Code: NEC 2023 300.4(D) (cables parallel to framing: 1-1/4 in. from the edge or a steel plate) · NEC 2023 300.4(A)(1) (bored holes 1-1/4 in. from the edge or a 1/16 in. steel plate)
Cut the plaster back to sound material and to the framing
Seal the room with plastic and put drop cloths down. Find the studs and lay out a rectangle whose left and right edges land on the center of a stud. Score the outline with a utility knife, then cut through the plaster with an oscillating tool so the edge stays clean and the plaster outside the line does not crack. Break out the plaster inside the line in small pieces and bag it as you go. Secure the plaster next to the opening with plaster washers if it feels loose.
Why: The new drywall needs solid support on its edges. The code says all edges and ends of gypsum board must land on framing members, except edges that run across the framing. Cutting to the center of the studs gives both the old wall and the new board something to fasten to, and a clean cut edge keeps the crack from running into the good plaster.
Code: 2024 IRC R702.3.5 (edges and ends of gypsum board on framing members)
Pull the lath and nails and check the framing
Pry off the wood lath inside the opening, pull or drive every lath nail flush, and brush the stud faces clean. Check each stud with a straightedge; old full-size lumber is often uneven. Plane down high spots, and add a full-length piece of 2x lumber beside any stud that is split, rotted or too far out of line. If you see termite damage, rot that keeps going, or a stud that was cut for old plumbing, stop and call a pro.
Why: Drywall is only as flat and strong as what it is screwed to. The code requires wood framing that supports gypsum board to be at least 2 inches nominal thickness, and only allows 1x2 furring strips when they go over solid backing or framing no more than 24 inches on center. Clean, flat studs let the new board sit flush with the old plaster.
Code: 2024 IRC R702.3.2 (wood framing 2 in. nominal; 1x2 furring over framing max 24 in. o.c.)
Check fireblocking while the wall is open
Look up and down inside the open stud bay. Many old houses are balloon framed, where the stud bay runs from floor to floor or into the attic with nothing to stop a fire. If the opening lets you reach the top or bottom of the bay at a floor or ceiling level and there is no wood block there, add a tight-fitting block of 2x lumber or pack the bay with unfaced mineral wool. Seal gaps around pipes and wires at the top and bottom plates with a fireblocking sealant.
Why: An open stud bay acts like a chimney. The code requires fireblocking in concealed spaces of stud walls vertically at the ceiling and floor levels, and at openings around pipes and wires at ceiling and floor level. Two-inch nominal lumber, 1/2 inch gypsum board and mineral wool batts are listed as acceptable fireblocking materials. A repair is the easiest time to close that path.
Code: 2024 IRC R302.11 (fireblocking at ceiling and floor levels and around penetrations) · 2024 IRC R302.11.1 (fireblocking materials)
Measure the old wall thickness and build the drywall out to match
Measure from the stud face to the face of the old plaster in several places around the opening. Plaster on lath is usually thicker than a single sheet of drywall, and it varies. Make up the difference with two layers of drywall (for example 3/8 inch plus 1/2 inch, or 1/4 inch plus 1/2 inch), or by screwing furring strips or shims to the stud faces and hanging the board on them. Test-fit a scrap: the face of the new board should be flush or a hair below the plaster, never proud of it.
Why: If the drywall face sits behind or in front of the plaster, the seam becomes a step you have to hide with a wide hump of compound that shows under paint and cracks later. The code requires a minimum board thickness for the framing spacing (3/8 inch only with studs 16 inches on center; 1/2 inch or more for 24 inches) and allows 1x2 furring strips over framing, so a 1/4 inch layer can be used to build up thickness but should not be the only layer.
Code: 2024 IRC Table R702.3.5 (minimum board thickness and framing spacing) · 2024 IRC R702.3.2 (furring strips over framing)
Use the right board for the room
Use standard gypsum board marked with its ASTM standard for dry rooms. In a bathroom or behind a sink, use a moisture-resistant board, but never regular or moisture-resistant drywall as the backer inside a tub or shower wall; that needs a cement or glass-mat backer board. If the ceiling plaster is failing too, use 1/2 inch sag-resistant or 5/8 inch ceiling board, hung across the joists, especially if it will get a spray or hand texture.
Why: The code requires gypsum board and accessories to meet listed ASTM standards such as ASTM C1396. Water-resistant gypsum backing board is allowed on bathroom walls and ceilings but not where it will be directly exposed to water or continuous high humidity. On ceilings that will get a water-based texture, the board must run perpendicular to the framing and be at least 1/2 inch at 16 inches on center or 5/8 inch at 24 inches (or 1/2 inch sag-resistant board), because wet texture makes thin board sag.
Code: 2024 IRC R702.3.1 (gypsum board materials, ASTM C1396 and others) · 2024 IRC R702.3.7 / R702.3.7.1 (water-resistant gypsum board and its limits) · 2024 IRC Table R702.3.5 notes (ceilings that receive water-based texture)
Fasten the new board with the right screws and spacing
Cut the board 1/8 inch smaller than the opening so it drops in without forcing the plaster edges. Screw the first layer to the studs, then the face layer, staggering its seams from the first layer if you can. Use Type W drywall screws long enough to go at least 5/8 inch into the wood after passing through every layer and shim. Space screws no more than 16 inches apart on walls with studs 16 inches on center (12 inches with studs at 24 inches, and 12 inches on ceilings). Set the heads just below the paper without tearing it.
Why: The code requires screws for wood framing to be Type W or Type S per ASTM C1002 and to penetrate the wood at least 5/8 inch. With two layers or furring, the usual 1-1/4 inch screw is too short, so the board can pull loose and crack the seams. Table R702.3.5 sets the maximum screw spacing so the board stays tight to the framing.
Code: 2024 IRC R702.3.5.1 (Type W or S screws, 5/8 in. into wood) · 2024 IRC Table R702.3.5 (maximum fastener spacing)
Bring electrical boxes out to the new wall surface
If there is a receptacle, switch or light box in the repaired area, check how far its front edge sits behind the new drywall face. Add a listed box extender or extension ring if it is set back more than 1/4 inch, and cut the drywall opening tight around the box. Fill any gap wider than 1/8 inch around the box with setting compound before the cover plate goes on. Leave the breakers off until the device is reinstalled and the plate is on.
Why: A thicker wall leaves old boxes recessed. In gypsum or plaster walls the code allows the front edge of the box, ring or extender to sit no more than 1/4 inch behind the finished surface, and the wall around the box must be repaired so no gap is larger than 1/8 inch. That keeps the device tight to the box and keeps sparks and heat inside it.
Code: NEC 2023 314.20 (box set back no more than 1/4 in. in gypsum or plaster) · NEC 2023 314.21 (no gaps larger than 1/8 in. around the box)
Tape the seams between the new board and the old plaster
Fill the gap between the drywall and the plaster edge with setting-type compound and let it harden. Bed paper tape (or mesh tape with setting compound) over every seam, including the plaster-to-drywall seams, and press it flat. Apply a second and third coat, each wider than the last, feathering out several inches onto the old plaster so the transition disappears. Let each coat dry and sand lightly with a sponge to keep the dust down.
Why: The joint between two different materials is where cracks show up first, because plaster and drywall move differently. Setting compound hardens by chemical reaction, fills deep gaps without shrinking much, and bonds well to old plaster. The code requires joint compound and joint tape to meet ASTM C475 and be installed as part of the gypsum board system.
Code: 2024 IRC R702.3.1 (joint compound and tape, ASTM C475)
Skim, match the texture, prime and paint
Old plaster is often smooth or hand-troweled while the new drywall paper has a different surface, so skim-coat the whole patch area (and the wall, if the old surface is badly cracked) with thin compound for a uniform finish. Match the existing texture if the wall has one, let it dry, then prime the patch with a drywall primer before painting the whole wall corner to corner so the sheen matches.
Why: Bare joint compound and drywall paper soak up paint differently than old painted plaster, which leaves a visible patch called flashing. The code requires interior wall finishes to be installed per Chapter 7 and to meet the flame spread limits of Section R302.9; standard drywall, joint compound and paint meet them, so do not cover the repair with foam panels or other combustible finishes to hide it.
Code: 2024 IRC R702.1 (interior finishes per Chapter 7 and R302.9) · 2024 IRC R302.9.1 (wall and ceiling finish flame spread index 200 max)
When to stop and call a licensed pro
- Your lead or asbestos test is positive, or you cannot test. Pros who work for pay in pre-1978 homes have to be lead-safe certified, and asbestos removal should be done by a qualified abatement contractor.
- The damaged plaster is on a ceiling, covers most of a room, or is sagging. Ceiling plaster is heavy and can fall in large pieces.
- You find knob-and-tube or cloth-covered wiring, scorched wires or boxes with no cover, or a box that has to move.
- There is a leak, mold or rot inside the wall, or the cracks keep coming back, which can mean the house is moving.
- The plaster is on brick, block or adobe instead of wood lath, or the wall is a garage-to-house wall that needs a fire separation.
- You want the whole room skim-coated and textured to match. See my texture matching and smooth finish services, or my guide on how to hang drywall sheets if you are replacing whole walls.
Common questions
Can I put drywall right over my old plaster walls instead of tearing them out?
Often yes, if the plaster is solid and well attached. You screw 1/4 or 3/8 inch drywall over it into the studs with screws long enough to get at least 5/8 inch into the wood (2024 IRC R702.3.5.1). Loose plaster has to be re-attached or removed first, and every electrical box has to be extended so it sits no more than 1/4 inch behind the new surface (NEC 2023 314.20). Window and door trim may need extension jambs.
Do I need a permit to repair a plaster wall in Phoenix?
Minor repair of non-structural parts, including patching walls or ceilings, is exempt from a building permit in the 2024 Phoenix Building Construction Code (Admin. 105.2, Building item 18). Moving framing, adding wiring or plumbing, or larger remodel work can need a permit. Other cities have their own lists, so check with yours.
How do I make the drywall patch flush with thick plaster?
Measure from the stud face to the face of the plaster and build the drywall out to that thickness with two layers of board or with furring strips and shims. Keep the new face flush or slightly below the plaster, never above it, and use longer screws so they still reach 5/8 inch into the wood.
Does old plaster contain asbestos?
Some can. Asbestos was used in some patching and joint compounds and textured paints until the CPSC banned asbestos patching compounds in 1977-1978 (16 CFR 1304.4). You cannot tell by looking, so have a sample tested by a qualified lab before you sand, cut or demolish it. If it is positive, hire an abatement pro.
Should I use setting compound or regular joint compound on plaster repairs?
Use setting-type compound to fill the gap and bed the tape where new drywall meets old plaster. It hardens chemically, shrinks less in deep fills and bonds well to plaster. Lightweight ready-mix compound is easier to sand for the final coats. Joint compound and tape should be products that meet ASTM C475 (2024 IRC R702.3.1).
Why do the cracks come back after I patch plaster?
Usually because the plaster around the crack has let go of the lath and keeps moving, or because the seam was filled without tape. Re-attach loose plaster with plaster washers, tape every seam, and cut back any section that sounds hollow. Cracks that keep growing, especially diagonal cracks at door and window corners, can mean the house is settling, and that should be looked at by a pro.
Want it done right the first time?
I repair plaster and drywall walls and ceilings across Phoenix, from cracks and holes to full sections of failed plaster, and finish them with matching texture and paint. See my drywall hole and crack repair in Phoenix, or send a request with the contact form and text me a photo for a fast estimate.
Licensed Phoenix, Arizona General Contractor ROC 367058 (R-62)