A garbage disposal that hums but will not spin, leaks from the bottom, or smells no matter what you do is one of the most common kitchen calls I get in Phoenix. Our hard water and the grease that goes down kitchen drains wear them out, and once the housing leaks, replacing the unit is the only real fix.
Swapping a disposal looks simple, but it is a plumbing job and an electrical job in the same cabinet: water, a drain trap, a dishwasher hose and a 120-volt motor a few inches apart. Below is the order I follow. Each step says why it matters and which 2024 plumbing code or 2023 National Electrical Code (NEC) section it comes from. If you are also replacing the faucet, see my guide on how to replace a faucet; if you would rather have it done, see my faucet and sink installation service.
Tools and parts
- New listed garbage disposal (look for ASSE 1008 and UL 430 on the box or label)
- Power cord kit listed for your disposal (if it does not come with a cord), or the hardwire parts in its manual
- Non-contact voltage tester and a plug-in receptacle tester with a GFCI test button
- Screwdrivers, channel-lock pliers and the disposal wrench (hex key) that comes with the unit
- Plumber's putty or the gasket the disposal manufacturer specifies for the sink flange
- Hammer and screwdriver (to knock out the dishwasher plug, only if you have a dishwasher)
- New slip-joint washers, or a new 1-1/2 in. trap kit
- Bucket, towels, flashlight and a small block of wood
- Safety glasses and gloves
Step-by-step
Buy a listed disposal that fits your sink and cabinet
Read the label on the old unit (brand, horsepower and whether it has a cord or is hardwired) and measure the space under the sink. Buy a disposal whose box or label shows it meets ASSE 1008 and is UL 430 listed. If you have a dishwasher, make sure the new unit has a dishwasher inlet. Buying the same brand often lets you reuse the same mounting ring, but I usually install the new ring and flange that come in the box.
Why: The plumbing code only allows domestic disposers that meet the ASSE 1008 performance standard and are listed to UL 430 for electrical safety. An unlisted import can leak, jam or overheat, and the code also requires listed equipment to be installed the way its instructions say, so read the manual before you start.
Code: IPC 2024 416.1 (food waste disposers: ASSE 1008, listed to UL 430) · NEC 110.3(B) (install listed equipment per its instructions)
Check the power under the sink before you start
Look at how the old disposal gets power. Most have a cord plugged into a receptacle inside the sink cabinet; some are hardwired into a box on the bottom of the unit and controlled by a wall switch. With a cord, the receptacle should be accessible, placed so the cord will not be pinched or crushed, and GFCI protected. Plug in a receptacle tester and press its GFCI button: if the power does not trip off, that receptacle (or the one feeding it) needs GFCI protection before the new disposal goes in.
Why: The 2023 NEC lets a disposal be cord-and-plug connected only with a grounding-type plug, a cord 18 to 36 inches long, and a receptacle that is accessible and located to protect the cord from damage. In a dwelling kitchen, the 2023 NEC requires GFCI protection for all 125-volt to 250-volt receptacles, not only the countertop ones, so the disposal receptacle needs it too. An accessible plug and receptacle can also serve as the disposal's required disconnect; a hardwired unit needs a disconnect that is within sight or lockable.
Code: NEC 422.16(B)(1) (disposer cord: grounding plug, 18 to 36 in., receptacle accessible and protected) · NEC 210.8(A)(6) (GFCI for all dwelling kitchen receptacles) · NEC 422.33(A) (accessible plug and receptacle as the disconnect) · NEC 422.31 (disconnect for permanently connected appliances)
Turn off the power, label the breaker and prove it is dead
Unplug the old disposal. If it is hardwired, find its breaker, switch it off, put tape over it, and fix the panel label if it was wrong or blank. Then check the wires in the disposal's electrical cover with a non-contact tester that you have just tried on a known live outlet. Leave the water off at the faucet the whole time.
Why: Flipping the wall switch only opens one wire, and many Phoenix panels are mislabeled. The code requires each circuit to be legibly identified by its purpose, and testing for absence of voltage at the point of work, with a tester checked on a live source, is the professional standard before touching conductors.
Code: NEC 408.4(A) (circuit directory / identification) · NFPA 70E-2024 120.6(7) (test for absence of voltage, verify the tester)
Disconnect the drain and remove the old disposal
Put a bucket under the trap. Loosen the slip nuts and remove the trap and the disposal's discharge tube. Pull the dishwasher hose off the disposal inlet. Support the disposal from below, then turn the lower mounting ring to the left (a screwdriver in one of the lugs gives you leverage) until the unit drops free. Remove the old sink flange from above and scrape off all the old putty.
Why: Taking the trap off first lets the drain water out into the bucket instead of the cabinet, and supporting the unit prevents a heavy motor from falling and cracking the sink or the trap arm. Cleaning the sink opening down to bare metal is what lets the new flange seal; old putty and scale leave a path for a slow leak.
Code: IPC 2024 405.9 (slip joints only at the trap inlet, outlet and within the trap seal)
Inspect the trap arm and vent before you reconnect anything
Look at the pipe that goes into the wall (the trap arm). It should come out of the wall roughly level with a slight fall toward the wall, with a P-trap below it. If the drain instead goes straight down through the cabinet floor with an S-shaped bend, or the trap arm is cracked, corroded or loose in the wall, do not just bolt the new disposal to it. Note how far the trap will sit from the wall connection.
Why: S-traps are prohibited because the water rushing down siphons the trap seal out and lets sewer gas into the kitchen. Each trap needs a vent within the distance the code allows (for a 1-1/2 inch trap, 6 feet of developed length at 1/4 inch per foot), or the trap can be siphoned. A new disposal changes where the trap sits, so this is the moment to catch a problem.
Code: IPC 2024 1002.3 (prohibited traps, including S traps) · IPC 2024 909.1 / Table 909.1 (maximum trap-to-vent distance)
Install the new sink flange and mounting ring
Roll a rope of plumber's putty (or use the gasket the manual specifies) under the new sink flange and press it into the sink opening. From below, slide on the fiber gasket, backup ring and mounting ring, then snap in the retaining ring. Tighten the mounting screws evenly, a little at a time, until the flange is drawn down tight and the putty squeezes out evenly. Wipe off the extra putty from the sink.
Why: The flange is the waste fitting between the sink and the disposal; it carries every gallon you run. Using the flange and gaskets made for the listed disposal (instead of mixing old and new parts) and tightening evenly gives a watertight seal that will not slowly drip onto the cabinet floor.
Code: IPC 2024 412.1.2 (waste fittings: ASME A112.18.2/CSA B125.2 or approved drainage standards) · NEC 110.3(B) (follow the listed unit's instructions)
Wire the disposal and connect the dishwasher drain
With the disposal on its side on a towel, open the electrical cover on the bottom. For a cord kit, connect black to black, white to white and the green ground wire to the green ground screw, tighten the cord's strain relief clamp, and close the cover. If you have a dishwasher, knock out the plug inside the dishwasher inlet with a screwdriver and hammer, and fish the loose plug out of the grinding chamber. Plan to route the dishwasher hose so it rises up and is fastened to the underside of the countertop before it drops to the disposal inlet.
Why: The cord must end in a grounding-type plug with the ground connected to the disposal's frame, and the cord length has to stay between 18 and 36 inches. Connections must be tight and made with terminals suited to the wire. For the dishwasher, the plumbing code allows its waste to connect directly to the disposal's dishwasher inlet, and the hose must rise and be secured to the underside of the counter so dirty sink water cannot flow back into the dishwasher. Forgetting the knockout plug is the most common reason a dishwasher stops draining after a disposal swap.
Code: NEC 422.16(B)(1) (grounding-type plug, 18 to 36 in. cord) · NEC 110.14 (electrical connections) · IPC 2024 409.4 (residential dishwasher waste: disposer inlet, high loop secured under the counter) · IPC 2024 409.2 (dishwasher water supply protected against backflow)

Hang the disposal and connect one trap
Lift the disposal (rest it on a block of wood or your knee), line up its three ears with the mounting ring, and turn the lower ring to the right until it locks. Attach the discharge tube with its gasket, then connect the tube to a 1-1/2 inch P-trap and the trap to the trap arm. On a double sink, both bowls should drain into the same single trap through a continuous waste; do not add a second trap. Turn the disposal so the discharge tube and dishwasher hose line up without strain, then lock it.
Why: Every fixture needs one trap, close to the outlet, and a fixture must never be double trapped: two traps in a row trap air between them and the sink drains slowly or gurgles. A two-bowl kitchen sink is allowed on one trap when the bowls are close in depth and the outlets are near each other. The code requires a disposal to drain into a pipe at least 1-1/2 inches, and a kitchen sink with a disposal needs at least a 1-1/2 inch trap, never larger than the pipe it drains into.
Code: IPC 2024 1002.1 (one trap per fixture, within 24 in. vertical, no double trapping; combination sink exception) · IPC 2024 416.2 (domestic disposer drain at least 1-1/2 in.) · IPC 2024 1002.5 and Table 709.1 (kitchen sink with disposer: 1-1/2 in. minimum trap)
Set the trap level and make the slip joints right
Use a new beveled washer on every slip nut, with the bevel facing the joint. Make sure the trap is level and the trap arm slopes slightly toward the wall. Hand-tighten the slip nuts plus about a quarter turn with pliers; do not crush plastic nuts. Do not glue or tape a slip joint, and do not use a trap with a flexible accordion section or a trap that depends on a moving part or an inside wall.
Why: Slip joints are only allowed at the trap inlet, the trap outlet and within the trap seal, and they must use an approved elastomeric gasket so they can be taken apart to clear a clog. Traps must be self-scouring, set level with respect to the seal, and hold a 2 to 4 inch water seal; a crooked or ribbed trap holds food scraps, loses its seal or clogs, and lets sewer gas in.
Code: IPC 2024 405.9 (slip-joint connections) · IPC 2024 1002.2 (self-scouring traps; slip joints with elastomeric gaskets) · IPC 2024 1002.4 (2 to 4 in. trap seal) · IPC 2024 1002.7 (traps set level)
Restore power and leak test with a full sink
Plug the disposal in (or turn the breaker back on) and press the GFCI test and reset buttons to confirm protection. Run cold water and turn the disposal on for a few seconds. Then put the stopper in, fill the bowl (both bowls on a double sink) and pull the stoppers at the same time so the whole drain runs full. Check the flange, the discharge tube, the dishwasher hose, every slip nut and the trap arm with a dry paper towel. Run the dishwasher drain cycle and check again.
Why: A trickle from the tap does not put the joints under the load a full sink does; most leaks show up only when the drain runs full. Testing the GFCI confirms the person reaching under a wet sink is protected, and keeping the slip joints where you can see and reach them is what the code expects so they can be checked and repaired later.
Code: NEC 210.8(A)(6) (GFCI protection in dwelling kitchens) · IPC 2024 405.9 (slip joints kept accessible)
Use cold water every time and keep the drain healthy
Always run cold water before, during and for a few seconds after you grind. Feed food scraps in a little at a time. Keep grease, oil, coffee grounds, eggshells, fibrous peels and bones out of it. If it jams, unplug it and turn the hex socket on the bottom with the wrench that came with it; press the red reset button after it cools.
Why: The plumbing code requires every disposer to have a cold water supply, because cold water keeps grease solid so it is chopped and carried away instead of coating the trap and the line in the wall. The kitchen faucet is that supply, and its spout above the sink rim keeps the water protected from backflow.
Code: IPC 2024 416.4 (cold water supply for disposers, protected against backflow)
When to stop and call a licensed pro
- There is no receptacle under the sink, it is not GFCI protected, or the disposal needs a new circuit or a new switch (new wiring usually needs a permit; check with your city).
- The drain is an S-trap through the cabinet floor, or the trap arm in the wall is cracked, corroded or loose.
- The sink drains slowly or gurgles even with a new trap, which can mean a vent or drain line problem in the wall.
- The cabinet floor is soft, stained or moldy from a leak that has been going on for a while.
- The sink is cracked, undermounted stone with a loose sink, or the old mounting ring is rusted to the sink.
- You are adding a disposal where there never was one, or moving the sink or dishwasher.
Common questions
Do I need a permit to replace a garbage disposal in Phoenix?
Swapping a disposal in the same place, plugged into the same receptacle, is usually treated as a repair, but rules differ by city and by job. Adding a new receptacle, circuit or switch, or adding a disposal where there was none, is new work, so check with your city's development services before you start.
Does a garbage disposal outlet need to be GFCI in Arizona?
Under the 2023 NEC, which Phoenix adopted with local amendments, all 125-volt to 250-volt receptacles in a dwelling kitchen need GFCI protection (210.8(A)(6)), including the one under the sink. Your city may enforce a different edition, so check your jurisdiction, but a GFCI-protected receptacle is the safe choice.
Can I plug a garbage disposal into an outlet, or must it be hardwired?
Either is allowed. NEC 422.16(B)(1) permits a cord-and-plug disposal when the cord is the type its instructions call for, has a grounding-type plug, is 18 to 36 inches long, and the receptacle is accessible and protected. A hardwired disposal needs a disconnect that is within sight or lockable.
Why does my sink gurgle or drain slowly after installing a disposal?
The most common causes are a second trap (the code says a fixture shall not be double trapped), a sagging or ribbed trap, a dishwasher knockout plug left in, or a vent problem in the wall. If the trap is a single, level 1-1/2 inch P-trap and it still gurgles, call a pro to check the vent.
How do I connect the dishwasher drain to a new disposal?
Knock out the plug inside the disposal's dishwasher inlet and remove it from the grinding chamber, then clamp the dishwasher hose to the inlet. The 2024 Phoenix plumbing code (409.4) also requires the hose to rise and be fastened to the underside of the counter before it drops to the disposal.
Should I run hot or cold water with a garbage disposal?
Cold. The plumbing code requires a cold water supply for disposers (416.4), and cold water keeps grease solid so it is ground and flushed away instead of coating the pipes.
Can a double kitchen sink use one trap with a disposal?
Yes, when the bowls are no more than 6 inches different in depth and the outlets are no more than 30 inches apart, a combination sink may be installed on one trap (IPC 2024 1002.1, exception 2). That is the normal setup: both bowls feed one 1-1/2 inch P-trap.
What can't I put down a garbage disposal?
Keep out grease and oil, coffee grounds, eggshells, bones, fibrous peels like celery and corn husks, and anything that is not food. Grind a little at a time with cold water running. Never pour chemical drain cleaner into a disposal.
Want it done right the first time?
I install and replace garbage disposals, kitchen sinks, faucets, traps, dishwasher drains and under-sink outlets across Phoenix. See my Faucet and sink installation in Phoenix, or send a request with the contact form and text me a photo for a fast estimate.
Licensed Phoenix, Arizona General Contractor ROC 367058 (R-62)